126 SITE DEVELOPMENT PLAN REVIEW
126.1 PURPOSE: Site development plans are necessary to provide for the
long-term planning, efficient and safe use of land, to promote high
standards in the layout, design, landscaping, construction and development
of land and structures, to minimize surface water drainage problems, to
protect adjoining properties from adverse conditions, and, to promote the
public health, safety and welfare of the citizens of Madison Township.
Many of our citizens, businesses, and agriculture-businesses are dependant
on having an adequate and safe ground water table, when site conditions
are favorable and conducive, a bio-retention or comparable system shall be
implemented to filter the surface water and to maintain the ground water
table nearly at the pre-construction level regarding both qualitatively
and quantitatively. Consultation with and subsequent approval from the
Lake County Soil and Water Conservation District is strongly recommended
for planning these systems.
126.2 REQUIREMENT: A site development plan shall be required and shall be
submitted for any use or development involving business activity, site
alteration, new construction, reconstruction, or modification of
structures in the R-4, R-5, P-1, B-1, B-2 and M-1 Zoning Districts or any
other Commercial or Industrial Zoning District. No activity shall commence
for any such use or project unless and until a site development plan has
been submitted according to the requirements as set forth in Section
126.7, and a valid Zoning Certificate has been issued for the said
project. Minor construction, reconstruction or alterations which do not
affect the purpose of Section 126 or surrounding properties shall not be
subject to the site plan review process, but shall be subject to
submitting all drawings, plans, or other documents as required to obtain a
Zoning Certificate.
126.3 PREPARATION: Site development plans shall be prepared and certified
by an architect, engineer, or land surveyor duly registered by the State
of Ohio. A landscape plan is required and may be prepared by a certified
landscape architect. Plans should be prepared at an appropriate scale.
126.4 CONTENTS: Site development plans shall contain the following
information:
a. The name of the owner and developer, north arrow, date, and scale;
b. The owners, zoning classification, and present use of adjoining
properties;
c. A boundary survey;
d. Existing topography and proposed finished grading with a maximum
contour interval of two feet (2’), existing trees over twelve inches (12”)
in diameter at four feet (4’) above grade, wooded areas, wetlands, and
other environmental features.
126-l
e. Locations and dimensions of all existing and proposed structures,
off-street parking, fencing, screening, buffers, drives, and walkways;
f. Provisions for adequate control and/or treatment of storm water;
g. All existing and proposed sanitary facilities indicating pipe sizes;
types, grades, invert elevations, and location of manholes;
h. All existing and proposed water facilities including line sizes and
locations, and hydrant locations;
i. Provisions for adequate storage and removal of solid waste;
j. Applicants must specify the number of, planting size and maximum size
of, and
location of trees to be planted. The applicant must specify the number of,
planting size and maximum size of, and the locations of all shrubs and
other flowering and non- flowering plantings to be used. Applicants are
recommended to consult with the Lake County Extension Office prior to
submittal.
k. Applicants shall submit proposed building elevations of all sides of
the building
including the location of all exterior doors, windows, and the exterior
finishes and/or facades to be used. Applicants shall submit the type and
texture of all exterior building materials. Roof-mounted HVAC equipment
shall be shown.
l. Locations and dimensions of all access drives and travel lanes,
adequate areas
allowing for delivery and/or emergency vehicles to turn around on site
must be
provided in the form of a cul-de-sac or comparable design;
m. All existing and proposed roadway elevations;
n Locations and elevations of adjacent structures;
o. Name, address, and phone number of the responsible State of Ohio
licensed architect, engineer or land surveyor and certification of work.
p. All proposed exterior lighting fixtures to be installed shall be shown
on the plan showing the overall illumination level in foot candle power of
the site. Employee
parking areas must be illuminated at least until after the last employee
has left the site.
q Minimal access cuts or driveway cuts are encouraged. Continuous curb
cuts are
126-2
prohibited. Developments utilizing only one access cut or driveway cut
onto a major highway system will be received more favorably by the
Commission. Upon proof of need and with the approval of other governing
agencies, approval of multiple cuts/driveways can be requested.
r. Number of parking spaces required and provided.
s. The type of surface in the parking and walk areas including curbs.
t. Minimum parking setback requirements, forty-feet (40’), subject to
Zoning Board Review.
126.5 DESIGN STANDARDS: All site plans shall conform to the following
design standards:
a. All proposed water and sanitary improvements shall be designed and
constructed in accordance with the standards and requirements of the Lake
County Department of Utilities, the Lake County General Health District,
and the Ohio Environmental Protection Agency,
b. Every use should be located within 300 feet of a fire hydrant or other
water source. Additional fire hydrants may be recommended by the Madison
Fire Chief and shall be located as directed by the Madison Fire Chief,
c. Development features, including building, parking areas, driveways,
etc., shall be so located and designed as to minimize adverse impacts on
adjacent properties. Maximum possible visual and auditory privacy for
surrounding properties shall be provided through good design and
landscaping buffers.
d. Building location and placement shall be developed with consideration
given to minimizing the removal of trees and changes of topography,
e. Where located adjacent to residentially zoned property, the required
set-back area shall be maintained with natural vegetation and shall have
supplemental plantings to provide visual and sound attenuation. Same
material to be used on the rear of the building, subject to Zoning Board
Review.
f. Where adjacent to non-residentially zoned property, the maximum lot
coverage of building, parking, drives, and other improvements shall be
ninety percent (90%). The remaining ten percent (10%) of the site shall be
landscaped with grass and plant material or retained in a natural state
with vegetative cover,
g. Building Exteriors shall not have long uninterrupted blan walls or
roofs. These features shall contain changes in plane, changes in texture,
windows, or other elements that divide these features;
126-3
h. Parking and service areas shall be screened from view from adjoining
residential properties. Screening of parking and service areas shall be
provided by means of landscaping, ornamental walls, fences or similar
means. Use of slow or low growing deciduous trees of various varieties
shall be used on the site. Lighting fixtures shall be placed to minimize
any effect on adjoining properties.
i. In parking areas designed to accommodate 30 vehicles or more, visual
relief shall be provided by means of landscaped dividers and/or islands,
j. Drives, travel lanes, and parking areas shall be designed and related
to public thoroughfares to provide for pedestrian and vehicular safety
both in the right-of-way and on the site. On-site circulation shall
provide for adequate access by emergency and safety vehicles. Adequate
areas shall be provided for snow removal vehicles and for snow retention.
k. Storm runoff provisions shall be designed based on a minimum one
hundred (100) year frequency design storm and the storm drainage
calculations submitted with the site plan. In all cases, the design shall
incorporate systems to maintain the ground water table nearly at the
pre-construction level. As the least desirable, the proposed outlet for
storm drainage shall be identified and an evaluation made of its capacity
to accommodate the projected flows. Where adequate capacity to handle
projected flows does not exist in the existing system, or where there is
no acceptable outlet, the applicant shall provide for either improvement
of the receiving drainage facility or on-site detention of sufficient
capacity and design to reduce post-development storm runoff to
pre-development levels for all design storms of one hundred (100) year
frequency or less
l. GROUND WATER MAPPING STANDARDS
1. The number of borings shall be sufficient such that no more than 100 ft
spacing exists between borings, measured in any direction. A minimum of 1
boring per lot shall be required.
2. A minimum of one groundwater monitoring well shall be installed within
each borehole. The well shall consist of a ¾ inch or larger slotted PVC
pipe that is backfilled to within 1 ft of grade with sand. The upper 1 ft
of the well shall consist of a capped, non-slotted PVC pipe, and the
annular space around the solid pipe shall be sealed with bentonite to
prevent groundwater from entering the well and affecting groundwater
measurements Follow-up groundwater measurements within the well shall be
taken 24 and 72 hrs. after installation.
126-4
3. The United States Geological Survey ground surface elevation at each
boring location shall be measured and presented on each boring log. The
following provides the minimum amount of information that must be
presented on the boring logs:
a. USGS ground surface elevation.
b. Date, time, and weather conditions at the time of drilling.
c. Company that completed the drilling, including company phone number and
address. The driller’s initials must also appear on the boring logs.
d. All ground water measurements including follow-up measurements shall be
marked as part of this log,
e. A sketch of the site depicting the exact well locations must be
submitted.
126.6 GENERAL REVIEW CRITERIA: The following general criteria must be used
to evaluate site plan requests.
a. Consistency with the township zoning resolution and with any applicable
plans in progress. The proposed development is consistent with zoning
regulations and the spirit of applicable areas, corridors, and
comprehensive plans, it would not adversely affect property near the site,
and it has been prepared to achieve the benefits of improved design;
b. Aesthetics and site planning. Architectural design, landscaping,
hardscaping, signage, and site planning conform to the zoning resolution
standards and good planning and design practices; compliments adjacent
development; and reinforces a unique, high-quality built, natural and
social environment. Community demographics, the presence of older
poor-quality development in the area and reducing development costs do not
justify low-quality of lowest-common-denominator design in accordance with
section 519.02 of the Ohio Revised Code.
c. Compatibility with surrounding uses. The proposed development is
compatible with the character of adjacent development and uses.
Compatibility includes but not limited to size, scale, mass, architectural
design, landscaping, and external effects. The presence of older poor
quality development in the area does not justify new development that is
similar.
d. Impact on existing infrastructure and public improvements. The proposed
development does adversely affect existing infrastructure and public
improvements, of that arrangements are made to mitigate such impacts.
e. Internal efficiency of design. The proposed design achieves internal
efficiency for its residents and/or visitors, adequacy of recreation,
public access, safety and other factors, including but not limited to
storm drainage, sewer and water, grades, dust control, and matters
relating directly to public health and safety.
f. Control of external effects. The proposed development controls external
effects on nearby land uses, movement and congestion of traffic, noise
generated, arrangement of signs, and lighting to prevent nuisances,
landscaping, features to prevent littering of accumulation of
126-5
trash, pollution, damage to environmentally sensitive areas, and other
factors that affect public health welfare and safety.
g. Adequacy of traffic and circulation plans. Designs and efficiency of
the traffic plan, vehicular and pedestrian circulation, adequacy and
convenience of parking, design of streets, linkage of collector streets to
the arterial street system are adequate and reflects good planning and
design practice. Access to the site from the public right-of-way does not
decrease the carrying capacity of the road, compromise driver and
pedestrian safety, incorporate excessive of continuous curb cuts, or
cheapen the appearance of development.
126.7 APPROVAL PROCESS:
a. Seven (7) complete sets of copies of the site development and building
plans shall be submitted to the Zoning Inspector at least thirty (30) days
prior to the requested meeting. The applicant shall forward one (1)
complete set of plans to the Madison Fire Department requesting written
comments.
b. The Zoning Inspector shall review site development plans for compliance
with the provisions of the Zoning Resolution and this Section. The Zoning
Inspector may forward said site development plans to an independent
engineer if additional review is needed. Said engineer shall review same
for conformity to the proper relation with existing or proposed sanitary
sewers, water lines, storm drainage, and existing grades of adjacent lands
and structures. The cost of such engineer’s review shall be borne by the
applicant and shall be in addition to such other fees as may from time to
time be established by the Trustees for processing and review of site
plans.
c. After review and approval by the Zoning Inspector and, if needed, the
Engineer the site development plans shall be reviewed by the Board of
Zoning Commission. An approval from the Board shall consist of 3
affirmative votes. If approved by the Board of Zoning Commission, the
signature of the Zoning Inspector shall be placed on the site development
plans and compliance with said plans shall become a condition of the
Zoning Certificate which may be issued for such development.
d. Correspondence from the Lake County Department of Utilities that
sufficient water and sanitary system capacity exists to accommodate the
proposed development shall be required. If an on-site sewage disposal
system is proposed, correspondence from the Lake County General Health
District /Ohio EPA that appropriate soils and land area for such system
exist on the site shall be required.
126-6
e. Approval of the site plan shall be contingent upon the applicant
receiving written approval from the Lake county Soil and Water
Conservation District, the Lake County Engineer, the Lake County General
Health District, the approval of the Lake County Storm Water Management
Engineer, the Ohio Environmental Protection Agency, the Lake County
Utilities Department, the Madison Fire District, and all other applicable
governing agencies. Copies of said written approval shall be presented to
the Zoning Inspector.
126.8 APPEAL OF APPROVED PLAN: The approval of the Zoning Commission and
the signature of the Zoning Inspector are final and may not be appealed to
the Board of Zoning Appeals and no variances there from may be granted by
the Board of Zoning Appeals. The Site Development Plan Review process is
not subject to review by, or the granting of exceptions or variances by
the Board of Zoning Appeals.
126-7
|